Switchboard Shock Safety Electrical Insulating Mat Manufacturing

HIC International produces Switchboard Shock Safety Insulating Mats - Dielectric Voltage Class 0,1,2,3,4, HV, MV, LV Voltages of 5KV~40KV Test Proof, an ISO 9001 certified Indian company.

Electrical Mats RFQ

Exported to Switzerland, Hongkong, USA, Saudi Arabia, UAE, China, Russia, Norway, Belgium, Japan, South Korea, Kuwait, France & other countries Electrical Control Panel Manufacturers & Industrial Automation Controls Producers as OEM High Voltage Carpet Rubber Insulation Sheet product importers.

Dielectric Voltage Class 0,1,2,3,4, HV, MV, 5KV~40KV Test Proof Electrical Insulating Mat

Leading manufacturing solutions of Dielectric Safety NEW Insulating Mats, high voltage protection:

  • HT, LT Control Panel-Boards Sparks Resistant, HIGH VOLTAGE MAT Rated as laid in IS 15652
  • Class A: 2 mm Thick, 10KV Proof voltage safe
  • Class B: 2.5 mm Thick, 22KV Proof
  • Class C: 3 mm Thick, 36KV Proof
  • Power Substation, DI-ELECTRIC CARPET Rated as laid in IEC 61111
  • Class 0: 2 mm Thick, 5KV Proof voltage safe
  • Class 1: 2.5 mm Thick, 10KV Proof
  • Class 2: 3 mm Thick, 20KV Proof
  • Class 3: 3.5 mm Thick, 30KV Proof
  • Class 4: 5 mm Thick, 40KV Proof
  • Switchgear, Fuse Boxes, NON-CONDUCTIVE MAT Rated as laid in ASTM D-178, ANSI JS.7
  • Class 0: 3.2 mm Thick, 5KV Proof voltage safe
  • Class 1: 4.8 mm Thick, 10KV Proof voltage safe
  • Class 2: 6.4 mm Thick, 20KV Proof
  • Class 3: 9.5 mm Thick, 30KV Proof
  • Class 4: 12.7 mm Thick, 40KV Proof
  • Electricity Generation, AC CURRENT RESISTANT CHEQUERED MATS Safety Rating as laid in IS 5424, 6 mm (0.4 KV Working); 8 mm (1KV work); 10 mm (7.5 KV work) ~ 20 mm Thick; 15KV voltage safety Proof
  • WIDTHS & LENGTHS: 1m, 1.2m, 1.5m: W and L: 2m, 5m, 7.5m, 10m, 15m, 20m, 25meters
  • COLOR: BLACK (standard), GREY, BLUE, RED
  • Anti-Slip FINISH: Textured (standard), Fine Ribbed, Chequered
Delivery Lead Time
Generally, within 4-6 weeks
Production Capacity
18,000 nos. per annum
A part unrolled roll of electrical insulating mat, marked 1000V, IEC 61111 Class 0 and 5kV test, 1000V working, beside a high voltage warning symbol, for switchboard safety from electric shock.
A corner of finely ribbed matting marked ASTM D178, 36,000 volts maximum, beside a high voltage warning symbol.
A blue insulating mat with a close textured surface, laid flat.
A red electrical rubber mat with a square grid pattern, labelled Electrical Rubber Mats, IS 5424:1969, beside a high voltage warning symbol.
Three rolls of black electrical matting standing together.
A roll of anti slip rubber flooring part unwound, round studs raised across its face.

Power Plant, Substation Non-Conductive Electrical Matting Solutions

Ensure worker safety with electrical anti-fatigue rubber floor insulating matting in:

  • HT and LT control rooms, transformer bays to resist impact, tears or punctures when protecting workers at Power plant high voltage switch room in front of energized switchboards.
  • Substation switchboard and switchgear where workers conduct routine maintenance, repair and installation of electrical equipment located in High voltage switchboards above 45 kV HV, Medium voltage above 1000 V to 45 kV MV, Low voltage up to 1000V LV to isolate operators from the ground, thus protecting them from shock.
  • Lab Test Passed, nonconductive floor mats solutions.
A dielectric carpet laid over cables on an office floor, its edge ramped and striped yellow and black.
Matting running the length of a control panel room, in front of the instrument boards.
Matting laid down the aisle of a switchroom between two rows of high tension panels.
Blue safety matting on the floor of a substation, running between the panels.
An operator working at a panel while standing on a rubber safety mat.

TC: Insulating Mat/ Tapis isolant/ Schaltanlagen-Matte

TEST CERTIFICATE of Insulating Mat/ Tapis isolant/ Schaltanlagen-Matte, TC while supplies w.r.t Di-electric, AC Proof Voltage, etc. Test Passed as per IEC 61111, ASTM D-178, IS 15652, IS 5424.

  • Insulating Mat
  • Tapis isolant
  • Schaltanlagen-Matte

Frequently asked questions

Which class of electrical insulating mat do I need for my working voltage?

Class, minimum thickness and working voltage: IEC/BS EN 61111: Class 0, 2 mm, 1 kV; Class 1, 2.5 mm, 7.5 kV; Class 2, 3 mm, 17 kV; Class 3, 3.5 mm, 26.5 kV; Class 4, 5 mm, 36 kV. ASTM D178: Class 0, 3.2 mm, 1 kV; Class 1, 4.8 mm, 7.5 kV; Class 2, 6.4 mm, 17 kV; Class 3, 9.5 mm, 26.5 kV; Class 4, 12.7 mm, 36 kV. IS 15652: Class A, 2 mm, 3.3 kV; Class B, 2.5 mm, 11 kV; Class C, 3 mm, 33 kV.

What is the difference between IEC 61111, ASTM D178 and IS 15652 mats?

i) IEC 61111 (BS EN 61111): Classes 0 to 4, minimum thickness 2 mm to 5 mm, working voltage 1 kV to 36 kV; textured or fine ribbed top. ii) ASTM D178: Classes 0 to 4, minimum thickness 3.2 mm to 12.7 mm, working voltage 1 kV to 36 kV; fine ribbed top. Type I is properly vulcanized matting; Type II also has one or more special properties: ozone, flame or oil resistance. iii) IS 15652: Classes A, B and C, minimum thickness 2 mm to 3 mm, working voltage 3.3 kV to 33 kV; dotted or textured top. IS 5424 is replaced by IS 15652 and IEC 61111, which meet more stringent safety requirements.

What sizes are switchboard mats supplied in?

Standard sizes: IEC 61111 mats 1 m, 1.2 m or 1.5 m wide x 2, 5, 10 or 15 m long; ASTM D178 mats 1 m, 1.2 m or 1.5 m wide x 7.5, 10 or 15 m long; IS 15652 mats 1 m, 1.2 m or 1.5 m wide x 10, 15, 20 or 25 m long. Thickness produced: 2 to 10 mm (IEC 61111), 3.2 to 14 mm (ASTM D178) and 2 to 8 mm (IS 15652).

Are switchboard mats fire retardant?

Yes. IS 15652 mats are of flame retardant quality. In HIC's quality testing, the fire retardant test passes when the blue flame is extinguished in less than 5 seconds after removal. HIC ASTM D178 Type II mats pass all the tests prescribed for Type II, including flame resistance.

What is the lead time for insulating mats?

Shipping time for insulating mats is generally within 4 to 6 weeks, or as stipulated in the quote and accepted order.

Can an IS 5424 mat be used in place of an IEC 61111 or IS 15652 mat?

IS 5424 mats, 6 mm to 20 mm thick, with dielectric test above 40 kV when new, 3,300 V working voltage and 15,000 V proof test, may be substituted with Class 0 of IEC 61111 or Class A of IS 15652, though this is not recommended. IS 5424 has become an old standard and is replaced by IS 15652 and IEC 61111, which meet more stringent safety requirements.

What warranty comes with switchboard insulating mats?

The manufacturer warrants insulating matting to be free from manufacturing defects and will replace or repair it if found defective in workmanship within 90 days from the date of shipment.

How are insulating mats marked for identification?

Each insulating mat roll is marked with Roll No., Class, Manufacturing Date and the manufacturer's identity, HIC Universal. Mats are tested in HIC's Testing Laboratory and stamped on the reverse with identification coding.

Get Quick Quote for reliable matting around switchboard accidental current leakage safety solutions.